This detail shows a flashing condition at a vertical wall or parapet.
Parapet roof flashing details.
Parapet wall with edge grip.
Wsrca suggests for walls 24 inches and taller that wall cladding be considered in lieu of membrane wall flashings per detail tp 8a.
Roof area divider curb type.
Sp 32 usp sp standard roof drain flashing detail.
Sp 35 usp sp vent stack flashing detail.
Ct 06 base flashing wall cover on wood parapet wall.
On walls greater than 36 inches high membrane wall flashing sheets are suggested to be strapped i e installed vertically.
The roof composition flashing extends up the cant strip over the coping and part way down its face under the copper flashing.
Detail drawing pdf pdf 195 kb.
Paraguard expansion joint roof to wall with parasolo flashing.
3 3a surface mounted counter flashing detail.
Parapet with plywood sheathing and parasolo flashing.
Paraguard expansion joint roof to roof with parasolo flashing.
Roofing cad details.
All of the good series of parapet details presented follow the baker principles and a little bit of other stuff figure 12a figure 12b figure 13 figure 14 and figure 15.
Sp 33 usp sp standard roof drain flashing detail for fastened systems.
Parapet with coping and parasolo flashing.
Copper base flashing which extends at least 8 up the wall.
Sp 34 usp sp scupper flashing detail.
Sp 30 usp sp alternate high wall flashing detail.
Typical roofing details autocad files.
Wall base termination detail.
Water control layer continuity.
Membranes continuous under the parapet flashing.
Mf 13 3 1 1 metal cap flashing joints mf 13 3 1 2 metal cap flashing inside corner mf 13 3 1 3 metal cap flashing parapet to wall transition site formed note.
Under e2 as1 all parapets must be flashed with a cap flashing having a 5 cross fall to prevent water accumulation.
Parapet with paraguard coping and parasolo flashing.
Where no structural damage has occurred and the cladding is sound the parapet should be cap flashed as shown below.
The counterflashing laps the base flashing a minimum of 3.
Air control layer continuity.
Detail drawing dwg.
High wall flashing detail 5 wide sheets.
Any modifications or changes to the certainteed drawings are the sole responsibility of the roof consultant architect designer or builder and certainteed assumes no responsibility or liability for any such modifications or changes.
The roofing squares are locked into a 20 oz.
The following pages are currently under construction mf 13 3 1 4 metal cap flashing parapet to wall transition shop formed.
This detail may be used where wall heights are 24 48 inches above roof surface.
High wall flashing detail 10 wide sheets.
Sp 31 usp sp parapet wall with usp sp clad metal flashing detail.